Humidity Conversion

By R.L. Snyder                                                (Revised March 24, 2005)

This Web page provides the equations used to make humidity conversions and tables of saturation vapor pressure. For a pdf file of this document, click on HumCon.pdf.  The saturation vapor pressure tables in an MS Excel spreadsheet can be downloaded by clicking on es.xls.

Barometric Pressure

Barometric pressure (P) in kPa from elevation (EL) in m above sea level was reported by Jensen, Burman and Allen, 1990 as

                                                                       (1)

Latent heat of vaporization

Latent heat of vaporization (l) in kJ kg-1 from air temperature (T) in oC

                                                                                              (2)

Saturation Vapor Pressure

Saturation vapor pressure over water is the vapor pressure of the air when the number of water molecules condensing equals the number evaporating from a flat surface of water with both the air and water at some temperature (T). An equation for the saturation vapor pressure (es) over water at temperature (T) in oC was given by Tetens (1930) as

                                                                                (3)

Values of es for T = -14.9 to 0 and for T = 0 to 49.9 are given in Tables 1 and 2.

When the number of water molecules sublimating equals the number depositing onto a flat surface of ice with both the air and ice at some temperature (T), the saturation vapor pressure (es) in kPa over ice at temperature (T) in oC was given by Tetens (1930) as

                                                                                  (4)

Values of es for T = 0 to -14.9 are given in Table 3.

Dew point and Ice point Temperature

Dew-point temperature (Td) in oC from air temperature (T) in oC and relative humidity (RH) in %

                                                                  (5)

Ice-point temperature (Ti) in oC from air temperature (T) in oC and relative humidity (RH) in %

                                                                    (6)

Note that the actual vapor pressure (e) is equal to the saturation vapor pressure (ed) at the dew-point temperature (Td) and, for subzero temperatures, e equals the saturation vapor pressure (ei) at the ice point temperature (Ti).

Dew-point temperature (Td) in oC from vapor pressure (e = ed) in kPa over water is calculated in two steps

                                                                                                (7)

                                                                                              (8)

Ice-point temperature (Ti) in oC from vapour pressure (e = ei) in kPa over ice is calculated in two steps

                                                                                                (9)

                                                                                              (10)

Psychrometric Constant

Psychrometric constant (g) in kPa oC-1 for liquid water as a function of barometric pressure (P) in kPa and wet-bulb temperature (Tw) in oC was given by Fritschen and Gay (1979) as

                                                                            (11)

Psychrometric constant (g) in kPa oC-1 for ice as a function of barometric pressure (P) in kPa and frost-bulb temperature (Tf) in oC is

                                                                           (12)

Vapor Pressure

Vapor pressure (e = ed) in kPa at the dew point temperature (Td) in oC

                                                                              (13)

Vapor pressure (e = ei) in kPa at the subzero ice point temperature (Ti) in oC

                                                                                (14)

Vapor pressure (e) in kPa from dry (T) and wet-bulb (Tw) temperature in °C and barometric pressure (P) and kPa

                                 (15)

where ew in kPa is the saturation vapor pressure at the wet-bulb temperature (Tw) in oC. It is calculated by substituting Tw for T in Equation 4.

Vapor pressure (e) in kPa from dry (T) and frost-bulb (Tf) temperature in °C and barometric pressure (P) in kPa

                            (16)

where ef is the saturation vapor pressure at the frost-bulb temperature. It is calculated by substituting Tf in oC for T in Equation 4.

Slope of Saturation Vapor Pressure

Slope of Saturation Vapor Pressure (D) in kPa oC-1 over liquid water with saturation vapor pressure (es) in kPa at temperature T in oC

                                                                                                (17)

Equivalent Temperature

Equivalent temperature (Te) in oC from temperature T in oC, vapor pressure e in kPa and the psychrometric constant g in kPa oC-1

                                                                                                        (18)

Absolute Humidity

Absolute humidity (c) in g m-3 from vapor pressure (e) in kPa and temperature (T) in oC

                                                                                                (19)

Table 1.  Saturation vapor pressure (es) in kPa over a flat surface of liquid water calculated using Tetens’ formula (Equation 4) for temperature between 0.0 °C and -14.9 °C.

Temperature (°C)
 -0.0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9
-140.2070.2050.2030.2020.2000.1990.1970.1950.1940.192
-130.2240.2230.2210.2190.2170.2160.2140.2120.2100.209
-120.2430.2410.2400.2380.2360.2340.2320.2300.2280.226
-110.2640.2620.2600.2580.2560.2530.2510.2490.2470.245
-100.2860.2830.2810.2790.2770.2750.2720.2700.2680.266
-90.3090.3070.3040.3020.3000.2970.2950.2930.2900.288
-80.3340.3320.3290.3270.3240.3220.3190.3170.3140.312
-70.3610.3590.3560.3530.3500.3480.3450.3420.3400.337
-60.3900.3870.3840.3810.3780.3760.3730.3700.3670.364
-50.4210.4180.4150.4120.4090.4050.4020.3990.3960.393
-40.4540.4510.4470.4440.4410.4370.4340.4310.4280.424
-30.4900.4860.4820.4790.4750.4720.4680.4650.4610.458
-20.5270.5240.5200.5160.5120.5080.5040.5010.4970.493
-10.5680.5640.5590.5550.5510.5470.5430.5390.5350.531
-00.6110.6060.6020.5980.5930.5890.5850.5800.5760.572

Table 2.  Saturation vapor pressure (kPa) over a flat surface of liquid water calculated using Tetens’ formula (Equation 4) for temperature between 0 °C and 49.9 °C.

Temperature (°C)
 0.00.10.20.30.40.50.60.70.80.9
00.6110.6150.6200.6240.6290.6330.6380.6430.6470.652
10.6570.6610.6660.6710.6760.6810.6860.6910.6960.701
20.7060.7110.7160.7210.7260.7310.7370.7420.7470.752
30.7580.7630.7690.7740.7800.7850.7910.7960.8020.808
40.8130.8190.8250.8310.8360.8420.8480.8540.8600.866
50.8720.8780.8850.8910.8970.9030.9100.9160.9220.929
60.9350.9420.9480.9550.9610.9680.9750.9810.9880.995
71.0021.0091.0161.0231.0301.0371.0441.0511.0581.065
81.0731.0801.0871.0951.1021.1101.1171.1251.1331.140
91.1481.1561.1641.1721.1791.1871.1951.2031.2121.220
101.2281.2361.2451.2531.2611.2701.2781.2871.2951.304
111.3131.3211.3301.3391.3481.3571.3661.3751.3841.393
121.4031.4121.4211.4311.4401.4491.4591.4691.4781.488
131.4981.5081.5171.5271.5371.5471.5581.5681.5781.588
141.5991.6091.6191.6301.6411.6511.6621.6731.6841.694
151.7051.7161.7271.7391.7501.7611.7721.7841.7951.807
161.8181.8301.8421.8531.8651.8771.8891.9011.9131.925
171.9381.9501.9621.9751.9872.0002.0132.0252.0382.051
182.0642.0772.0902.1032.1162.1302.1432.1572.1702.184
192.1972.2112.2252.2392.2532.2672.2812.2952.3092.324
202.3382.3532.3672.3822.3972.4122.4272.4422.4572.472
212.4872.5022.5182.5332.5492.5642.5802.5962.6122.628
222.6442.6602.6762.6932.7092.7262.7422.7592.7762.792
232.8092.8262.8442.8612.8782.8962.9132.9312.9482.966
242.9843.0023.0203.0383.0563.0753.0933.1123.1303.149
253.1683.1873.2063.2253.2443.2633.2833.3023.3223.342
263.3613.3813.4013.4223.4423.4623.4833.5033.5243.544
273.5653.5863.6073.6293.6503.6713.6933.7143.7363.758
283.7803.8023.8243.8463.8693.8913.9143.9373.9603.983
294.0064.0294.0524.0764.0994.1234.1474.1714.1954.219
304.2434.2674.2924.3174.3414.3664.3914.4164.4424.467
314.4934.5184.5444.5704.5964.6224.6484.6754.7014.728
324.7554.7824.8094.8364.8634.8914.9184.9464.9745.002
335.0305.0585.0875.1155.1445.1735.2025.2315.2605.290
345.3195.3495.3795.4095.4395.4695.5005.5305.5615.592
355.6235.6545.6855.7175.7485.7805.8125.8445.8765.908
365.9415.9746.0076.0396.0736.1066.1396.1736.2076.241
376.2756.3096.3436.3786.4136.4486.4836.5186.5536.589
386.6256.6616.6976.7336.7696.8066.8436.8806.9176.954
396.9917.0297.0677.1057.1437.1817.2207.2587.2977.336
407.3767.4157.4557.4947.5347.5747.6157.6557.6967.737
417.7787.8197.8617.9027.9447.9868.0288.0718.1138.156
428.1998.2428.2858.3298.3738.4178.4618.5058.5508.595
438.6408.6858.7308.7768.8218.8678.9148.9609.0079.053
449.1019.1489.1959.2439.2919.3399.3879.4369.4849.533
459.5829.6329.6819.7319.7819.8329.8829.9339.98410.035
4610.08610.13810.19010.24210.29410.34710.39910.45210.50610.559
4710.61310.66710.72110.77510.83010.88510.94010.99511.05111.107
4811.16311.21911.27611.33311.39011.44711.50411.56211.62011.679
4911.73711.79611.85511.91411.97412.03412.09412.15412.21512.276

Table 3.  Saturation vapor pressure (kPa) over a flat surface of ice calculated using Tetens’ formula (Equation 5) for temperature between 0.0 °C and -14.9 °C.

Temperature (°C)
 0.0-0.1-0.2-0.3-0.4-0.5-0.6-0.7-0.8-0.9
-140.1810.1790.1770.1760.1740.1730.1710.1690.1680.166
-130.1980.1960.1940.1930.1910.1890.1870.1860.1840.182
-120.2170.2150.2130.2110.2090.2070.2050.2040.2020.200
-110.2370.2350.2330.2310.2290.2270.2250.2230.2210.219
-100.2590.2570.2550.2530.2500.2480.2460.2440.2420.239
-90.2840.2810.2790.2760.2740.2710.2690.2660.2640.262
-80.3100.3070.3040.3020.2990.2960.2940.2910.2890.286
-70.3380.3350.3320.3290.3260.3230.3210.3180.3150.312
-60.3680.3650.3620.3590.3560.3530.3500.3470.3440.341
-50.4010.3980.3950.3910.3880.3850.3810.3780.3750.372
-40.4370.4330.4300.4260.4220.4190.4150.4120.4080.405
-30.4760.4720.4680.4640.4600.4560.4520.4480.4450.441
-20.5170.5130.5090.5050.5000.4960.4920.4880.4840.480
-10.5620.5580.5530.5480.5440.5390.5350.5300.5260.522
00.6110.6060.6010.5960.5910.5860.5810.5760.5720.567

References

Fritschen, L.J. & Gay, L.W.  1979.  Environmental Instrumentation. New York, NY: Springer-Verlag.

Jensen, M.E., R.D. Burman, and R.G. Allen, Eds. 1990. Evapotranspiration and Irrigation Water Requirements. Amer. Soc. of Civil Eng., New York.

Tetens, V.O. 1930. Uber einige meteorologische. Begriffe, Zeitschrift fur Geophysik. 6:297-309.